Indexing fails during end of Daylight Saving Time in SAS® Visual Investigator


Indexing in SAS Visual Investigator fails when the job spans the ending time frame of Daylight Saving Time in the Fall. This issue occurs because the end date is earlier than the start date. Note that this issue does not occur during the start of Daylight Saving Time in the Spring.

Below are examples of log entries from the svi-indexer and svi-feature services.

svi-indexer log:

2025-10-26 02:40:15.585  INFO 726541 --- [   jobLauncher1] o.s.b.c.l.support.SimpleJobLauncher      : service@@xxx [df7bbfe2d7981ddc] Job: [FlowJob: [name=indexerJob]] launched with the following parameters: [{jobId=15f7e032-00ee-4f4c-9005-6417ec71155f, operation=INCREMENTAL_LOAD, reindexAllSystemLinks=false, reindexJobType=REINDEX_ONE, reindexAllSystemTransactions=false, tenant=xxx, incrementalDate=2025-10-25T23:40:13.737Z}]

svi-feature log:

2025-10-26 02:40:16.391 ERROR 726465 --- [cTaskExecutor-1] c.s.e.c.config.rabbitmq.MessageConsumer  : service@@xxx Consumer 'com.sas.feature.service.job.JobEventListener' failed to process event: The task with the ID "e9a02edc-bf9b-4d91-bf7a-7fcd1e66e26c" must have start date that is earlier than or equal to the end date.

svi-indexer log:

2025-10-26 02:40:19.776  INFO 726541 --- [   jobLauncher1] o.s.b.c.l.support.SimpleJobLauncher      : service@@xxx [df7bbfe2d7981ddc] Job: [FlowJob: [name=indexerJob]] completed with the following parameters: [{jobId=15f7e032-00ee-4f4c-9005-6417ec71155f, operation=INCREMENTAL_LOAD, reindexAllSystemLinks=false, reindexJobType=REINDEX_ONE, reindexAllSystemTransactions=false, tenant=xxx, incrementalDate=2025-10-25T23:40:13.737Z}] and the following status: [COMPLETED] in 4s184ms

A failure is displayed on the Jobs tab, but the indexing job successfully completes.

Workaround

This issue is a known defect.

To work around this issue, avoid indexing during the span of the time shift in the Fall.